  • 1(1711069701843).png

200kW fuel cell system test system


GR-FCTS-E200K series is water-cooled hydrogen fuel cell system test system, the product is suitable for the power of 50kW ~ 200kW hydrogen fuel cell system testing and research and development. The test equipment has precise control and monitoring functions. Through standardizing the test scheme process, improving and optimizing the hardware process flow, the dynamic response accuracy and speed of testing high power output are achieved, and the development of fuel cell system and the accuracy and consistency of production data are ensured. The system has a way of using ergonomics and a powerful human-computer interaction interface. Its control system adopts international high-end brands and reserves external key communication interfaces, such as CAN, LAN and RS232 serial ports. It has the advantages of high vehicle matching and precise control.

Product Details

Product Overview

GR-FCTS-E200K series is water-cooled hydrogen fuel cell system test system, the product is suitable for the power of 50~200kW hydrogen fuel cell system testing, research and development. The test equipment has precise control and monitoring functions. Through standardizing the test scheme process, improving and optimizing the hardware process flow, the dynamic response accuracy and speed of testing high power output are achieved, and the development of fuel cell system and the accuracy and consistency of production data are ensured. The system has a way of using ergonomics and a powerful human-computer interaction interface. Its control system adopts international high-end brands and reserves external key communication interfaces, such as CAN, LAN and RS232 serial ports. It has the advantages of high vehicle matching and precise control.

 

Product Features

● High-precision inlet gas mass flow controller

● Automatic thermal balance management system during reactor operation

● With high-precision combustible gas leakage alarm function

● Built-in multi-function controller, stable performance

● Capable of polarization curve, steady-state operation and dynamic response test

● Supporting the fuel cell system with professional monitoring software which can be developed many times

● With constant power, constant current, constant voltage discharge mode, programmable automatic operation function

 

Product Functions

● Hydrogen emission test of fuel cell engine

● Fuel cell engine air tightness test

● Normal temperature idle cold start characteristic test of fuel cell engine

● Fuel cell engine normal temperature rated power cold start test

● Normal temperature idle hot start test of fuel cell engine

● Fuel cell engine steady-state characteristic test

● Normal temperature rated power hot start test of fuel cell engine

● Fuel cell engine rated power test

● Peak power test of fuel cell engine

● Dynamic response characteristic test of fuel cell engine

● Fuel cell engine dynamic average efficiency characteristic test

● Fuel cell quality and power density testing

● Hydrogen utilization test

● Shutdown strategy verification

 

Product Parameters

Model GR-FCTS-E100K GR-FCTS-E150K GR-FCTS-E200K GR-FCTS-E250K GR-FCTS-E300K GR-FCTS-E350K GR-FCTS-E400K
Rated power 100kW 150kW 200kW 250kW 300kW 350kW 400kW
Hydrogen flow control range 20~2000SLPM 30~3000SLPM 40~4000SLPM 50~5000SLPM 60~6000SLPM 70~7000SLPM 80~8000SLPM
Hydrogen flow control accuracy ±(0.8%RD+0.2%F.S.)
Nitrogen purge Have
Test system outlet hydrogen pressure control range 0.1~1.6MPa
Hydrogen front end pressure control accuracy ± 2kPa (steady state)
Pressure control mode Manual mechanical pressure regulating valve
Coolant Deionized water
Coolant flow measurement accuracy ≤ ± 1% F.S.
Temperature control accuracy ± 1 ℃ (steady state)/± 2 ℃ (dynamic) (with heating function)
Coolant temperature control range RT~90℃
Waterway purging function Have
Hydrogen leak alarm 1000-40000ppm (alarm limit can be set), three-level fault alarm
On-line insulation detection Impedance protection limit can be set, three fault alarm
Sound and light alarm Have
Emergency stop With emergency stop switch and three-color operation status indicator
Safety interlock Overtemperature, Overpressure, Undervoltage, Overload
Working environment 380V,50Hz,0~45℃,0~90%RH