Product Details

AEM Electrolyzer Test Bench Product Power Level Overview

 

Serial Number

Number

Name

Model

1

1

(Desktop; Atmospheric Pressure)

100W AEM Electrolyzer Test Bench

GR-WETS-AEM-SC100

2

500W AEM Electrolyzer Test Bench

GR-WETS-AEM-SC500

3

2

500W AEM Electrolyzer Test Bench

GR-WETS-AEM-SC500

4

1kW AEM Electrolyzer Test Bench

GR-WETS-AEM-S1K

5

5kW AEM Electrolyzer Test Bench

GR-WETS-AEM-S5K

6

25kW AEM Electrolyzer Test Bench

GR-WETS-AEM-S25K

7

50kW AEM Electrolyzer Test Bench

GR-WETS-AEM-S50K

8

100kW AEM Electrolyzer Test Bench

GR-WETS-AEM-S100K

9

250kW AEM Electrolyzer Test Bench

GR-WETS-AEM-S250K

10

3 (Multi-channel)

4-channel 300W AEM Electrolyzer Test Bench (Fully Independent)

GR-WETS-AEM-SC300X4D

11

4-channel 300W AEM Electrolyzer Test Bench (Fully Shared)

GR-WETS-AEM-SC300X4G

12

 

 

 

 

AEM Electrolyzer Test Bench Product Overview

1.1 Product Images

Serial Number

Type

Image

Image

1

Desktop AEM Electrolyzer Test Bench

2

AEM Electrolyzer Test Bench

3

Multi-channel AEM Electrolyzer Test Bench

1.2 Product Overview

The GR-WETS-AEM series electrolyzer test bench is designed to provide an accurate and reliable testing platform for electrolyzers. This test bench has undergone multiple upgrades and optimizations based on the performance of existing products in the industry. It consists of an electrolyte circulation system, nitrogen purging unit, gas-liquid separation unit, gas analysis pretreatment unit, PLC acquisition and control unit, human-machine operation unit, and safety monitoring unit, using the company's self-developed system testing software to meet the testing needs for polarization curves, hydrogen production energy consumption efficiency, hydrogen quality testing, and product lifespan.

1.3 Product Functions

Nitrogen Purging: Equipped with automatic nitrogen purging function before and after testing, and during equipment failure/shutdown.

Electrolyte Control: Features a wide range, high precision, and high stability control function for circulating electrolyte flow, meeting various testing requirements; includes alkaline solution concentration monitoring; and has functions for heating circulating electrolyte, liquid level monitoring, and automatic water replenishment.

Gas-Water Separation: Features an efficient gas-water separation design, including gas-liquid separation, washing, condensation dehumidification, and drying devices.

Pressure Control: Equipped with automatic back pressure control for anode/cathode; includes gas equalization and differential pressure control functions on both sides.

Flow Detection: Features online high-precision measurement of gas flow.

Data Acquisition and Storage: Capable of real-time acquisition and monitoring of data such as current, voltage, temperature, pressure, and circulating electrolyte flow.

Safety Interlock and Protection: Features dual safety protection strategies (hardware and software), with three-level alarm parameters settable via upper computer software.

Performance Testing: Capable of testing functions such as electrolyzer polarization curve testing, small chamber consistency, durability testing, and sensitivity testing.

Stability and Reliability: Capable of 24-hour unattended operation.

1.4 Product Advantages

High Control Stability: Steady-state temperature control ±1℃; pressure control ±0.5%F.S.; electrolyte flow control ±1%F.S.

High Measurement Accuracy: Temperature ±0.5℃; pressure ±0.5%F.S.; circulating electrolyte flow ±1%F.S.; gas flow ±0.8%RD+0.2%F.S.

High Integration Level: Highly integrated equipment, compact layout, aesthetically pleasing design, convenient operation, and complete interface functions.

Strong Data Processing Capability: Able to automatically collect, analyze, and process data, generating detailed test results, including charts and data lists.

High Equipment Safety: Complete safety protection and interlock functions, with three-level safety alarm limits settable via upper computer.

Strong Equipment Reliability: Equipment features various automatic condition testing functions, capable of 7×24 hours unattended operation.

Multiple Function Expansion: Can integrate with electrochemical workstations for electrochemical testing; can be expanded to achieve electrolyzer polarization loss decomposition, EIS data analysis functions, etc.

1.5 Product Parameters

1.5.1 Desktop AEM Electrolyzer Test Bench

Model

GR-WETS-AEM-SC100

GR-WETS-AEM-SC500

Rated Power

100W

500W

Electrolyzer Type

AEM Electrolyzer

System Module

Technical Indicators

Specific Parameters

Electrolyte Circulation Module

Medium

1M KOH Solution

Circulation Mode

Anode Independent Supply/Cathode Independent Supply/Both Sides Independent Supply

Alkaline Solution Concentration

Equipped with alkaline solution concentration detection function; detection range: 0~40%; accuracy: ±1%F.S.

Electrolyte Flow

0.05~0.5L/min

Temperature Control

RT~90℃; steady-state temperature control accuracy: ±1℃; heating rate: 1~4℃/min

Automatic Water Replenishment

Equipped with

Hydrogen/Oxygen System Module

Hydrogen Flow

0~0.5SLPM

0~2.5SLPM

Back Pressure Range

Atmospheric Pressure

Dehydration Function

Equipped with gas-liquid separation, washing, condensation dehumidification, drying

Nitrogen Purging

Purging Function

Equipped with automatic/manual nitrogen purging function before/after testing, customizable purging time

Gas Analysis

Hydrogen in Oxygen

Range: 0~4%VOL; Accuracy: ±2%F.S. (Calibration available for range 0~5%VOL)

Power Module

Operating Mode

Constant Pressure, Constant Current, Constant Power, Programmable Automatic Operation

Voltage

0~20V

0~16V

Current

0~100A

0~250A

Voltage Inspection

Voltage Inspection

Equipped with individual voltage inspection function; Number of channels: customizable; Range: ±3V; Accuracy: ±1mV; Alarm limit can be set

Whole System

Controller

PLC

Upper Computer

Optional C# or Labview

Communication Interface

LAN

Power Supply

AC220V/50Hz

Overall Structure

Desktop Type

Optional Functions

Fixture; Oxygen Flow Detection; Hydrogen in Oxygen Detection; Dew Point Detection; Electrochemical Workstation; Electrochemical Testing; Polarization Loss Decomposition and EIS Data Analysis Function

Note: Upgrades or downgrades can be made according to requirements.

1.5.2 AEM Electrolyzer Test Bench

Model

GR-WETS-AEM-SC500

GR-WETS-AEM-S1K

GR-WETS-AEM-S5K

GR-WETS-AEM-S25K

GR-WETS-AEM-S50K

GR-WETS-AEM-S100K

GR-WETS-AEM-S250K

Rated Power

500W

1kW

5kW

25kW

50kW

100kW

250kW

Electrolyzer Type

AEM Electrolyzer

System Module

Technical Indicators

Specific Parameters

Electrolyte Circulation Module

Medium

1M KOH Solution

Circulation Mode

Anode Independent Supply/Cathode Independent Supply/Both Sides Independent Supply

Alkaline Solution Concentration

Equipped with alkaline solution concentration detection function; detection range: 0~40%; accuracy: ±1%F.S.

Electrolyte Flow

1L/min

2L/min

8L/min

40L/min

80L/min

160L/min

400L/min

Temperature Control

RT~90℃; steady-state temperature control accuracy: ±1℃; heating rate: 1~4℃/min

Automatic Water Replenishment

Equipped with

Hydrogen/Oxygen System Module

Hydrogen Flow

2.5SLPM

5SLPM

25SLPM

125SLPM

250SLPM

500SLPM

1250SLPM

Back Pressure Range

0~3.2MPa; Control Accuracy: ±1%F.S.; Equipped with gas equalization and differential pressure control functions on both sides

Dehydration Function

Equipped with gas-liquid separation, washing, condensation dehumidification, drying

Nitrogen Purging

Purging Function

Equipped with automatic/manual nitrogen purging function before/after testing, customizable purging time

Gas Analysis

Hydrogen in Oxygen

Range: 0~4%VOL; Accuracy: ±2%F.S. (Calibration available for range 0~5%VOL)

Power Module

Operating Mode

Constant Pressure, Constant Current, Constant Power, Programmable Automatic Operation

Voltage

Custom services provided based on actual needs

Current

Custom services provided based on actual needs

Voltage Inspection

Voltage Inspection

Equipped with individual voltage inspection function; Number of channels: customizable; Range: ±3V; Accuracy: ±1mV; Alarm limit can be set

Whole System

Controller

PLC

Upper Computer

Optional C# or Labview

Communication Interface

LAN

Power Supply

AC220V/50Hz or AC380V/50Hz

Overall Structure

Rack Type

Cabinet/Container/Skid Mounted

Optional Functions

Oxygen Flow Detection; Hydrogen in Oxygen Detection; Dew Point Detection; Electrochemical Testing; Polarization Loss Decomposition and EIS Data Analysis Function

Note: Upgrades or downgrades can be made according to requirements.

1.5.3 Multi-Channel AEM Electrolyzer Test Bench

Model

GR-WETS-AEM-SC300X4D

GR-WETS-AEM-SC300X4G

Single Channel Rated Power

300W

Electrolyzer Type

AEM Electrolyzer

Channel Form

4 Independent Channels

4 Shared Channels

System Module

Technical Indicators

Specific Parameters

Electrolyte Circulation Module

Medium

1M KOH Solution

Circulation Mode

Anode Separate Liquid Supply/Cathode Separate Liquid Supply/Dual Side Independent Liquid Supply, 4 Independent Channels

Alkaline Solution Concentration

All 4 channels equipped with alkali liquid concentration detection function

Detection Range: 0~40%; Accuracy: ±1%F.S.

Shared 1 set of alkali liquid concentration detection function

Detection Range: 0~40%; Accuracy ±1%F.S.

Electrolyte Flow

0.05~0.5L/min

Temperature Control

RT~90℃; steady-state temperature control accuracy: ±1℃; heating rate: 1~4℃/min

Automatic Water Replenishment

Equipped with

Hydrogen/Oxygen System Module

Hydrogen Flow

Single Channel 0~1.5SLPM

0~6SLPM

Back Pressure Range

4 Independent Channels Back Pressure, 0~3.2MPa

4 Shared Channels Back Pressure, Maximum 0~3.2MPa

Dehydration Function

All 4 channels equipped with gas-liquid separation, washing, condensation dehumidification, drying

Shared 1 set of gas-liquid separation, washing, condensation dehumidification, drying

Nitrogen Purging

Purging Function

Equipped with automatic/manual nitrogen purging function before/after testing, customizable purging time

Gas Analysis

Hydrogen in Oxygen

Range: 0~4%VOL; Accuracy: ±2%F.S. (Calibration available for range 0~5%VOL)

Single Channel Power Module

Operating Mode

Constant Pressure, Constant Current, Constant Power, Programmable Automatic Operation

Voltage

0~20V

Current

0~100A

Voltage Inspection

Voltage Inspection

Equipped with individual voltage inspection function; Number of channels: customizable; Range: ±3V, Accuracy: ±1mV; Alarm limit can be set

Whole System

Controller

PLC

Upper Computer

Optional C# or Labview

Communication Interface

LAN

Power Supply

AC220V/50Hz or AC380V/50Hz

Overall Structure

Rack Type

Optional Functions

Independent detection/switching inspection of oxygen flow; Switching inspection of hydrogen in oxygen; Independent detection/switching inspection of oxygen in hydrogen; Dew Point Detection; Electrochemical Testing; Polarization Loss Decomposition and EIS Data Analysis Function

Note: Upgrades or downgrades can be made according to requirements.

 

Key words:

Fuel Cell Stack Test Equipment丨Fuel Cell丨Control

Previous:

Related Products


AEM Electrolyzer Test Bench

Large Area Fuel Cell Partition Detection Device

Fuel Cell Partition Detection Fixture

Visualized PEM Electrolyzer Fixture

Online consultation


Product Name:

Submit