  • 200kW燃料电池堆测试台(1713511069580).png

200kW fuel cell stack test bench


The GR-FCTS-S200K series fuel cell test bench is a performance testing system developed and manufactured by Beijing Gerui Energy Technology Co., Ltd., designed to test hydrogen-air/hydrogen-oxygen fuel cell units with a power range of 50 to 200 kW. This testing system has undergone multiple upgrades, improvements, and optimized designs based on the performance of existing products in the industry. With optimized hardware architecture and precise software algorithms, combined with nonlinear system parameter identification and multivariable optimization control technology for fuel cells, it achieves precise and controllable operating parameters. Additionally, simulation models for micrometer/millimeter-level liquid water transfer and impedance analysis are established based on data mining and parameter identification technology, providing users with comprehensive lifecycle data service analysis for the batteries.

Product Details

Overview of Fuel Cell Test Bench Product Power Levels

Serial Number

Number

Name

Model

1

1

(Desktop Type)

100W Fuel Cell Test Bench

GR-FCTS-SC100

2

300W Fuel Cell Test Bench

GR-FCTS-SC300

3

2

1kW Fuel Cell Stack Test Bench

GR-FCTS-S1K

4

5kW Fuel Cell Stack Test Bench

GR-FCTS-S5K

5

10kW Fuel Cell Stack Test Bench

GR-FCTS-S10K

6

30kW Fuel Cell Stack Test Bench

GR-FCTS-S30K

7

50kW Fuel Cell Stack Test Bench

GR-FCTS-S50K

8

100kW Fuel Cell Stack Test Bench

GR-FCTS-S100K

9

200kW Fuel Cell Stack Test Bench

GR-FCTS-S200K

10

400kW Fuel Cell Stack Test Bench

GR-FCTS-S400K

 

 

Overview of Fuel Cell Test Bench Products

1.1 Product Images

 

Serial Number

Type

Image

Image

1

Desktop Fuel Cell Test Bench

2

Fuel Cell Stack Test Bench

 

1.2 Product Overview

The GR-FCTS series fuel cell test bench is designed to provide an accurate and reliable testing platform for fuel cell stacks. This test bench has undergone multiple upgrades and optimizations based on the performance of existing products in the industry. Through hardware architecture optimization and precise software algorithms, as well as the identification of nonlinear system parameters and multivariable optimization control technology for fuel cells, it achieves precise and controllable operating parameters. Simulation models for micrometer/millimeter-level liquid water transfer and impedance analysis are established based on data mining and parameter identification technology, providing users with battery lifecycle data service analysis.

This test bench consists of a gas supply unit, pressure control unit, temperature adjustment unit, humidity adjustment unit, PLC acquisition and control unit, human-machine operation unit, and safety monitoring unit. It uses the company's self-developed system testing software, which can meet the testing functions of polarization curve testing, steady-state operation, dynamic response testing, activation testing, sensitivity testing, and durability testing for fuel cells. It is suitable for the research and testing of fuel cell single cells, short stacks, complete stacks, components, and material levels.

 

1.3 Product Functions

Nitrogen Purging: Equipped with automatic nitrogen purging function before and after testing, and during equipment failure/shutdown.

Flow Control: Equipped with high-precision gas flow control function.

Pressure Control: Equipped with a high-precision gas back pressure control system.

Gas Supply: Equipped with gas supply setting functions, including fixed flow setting, stoichiometric ratio setting, gas pressure setting, etc.

Gas Humidity Adjustment: Uses bubbling/spraying humidification; equipped with automatic replenishment function for humidification water consumption; allows arbitrary switching between gas dry and wet modes.

Gas Temperature Adjustment: Temperature is controlled by PID; equipped with an automatic thermal balance management system during fuel cell operation.

Data Acquisition and Storage: Equipped with real-time data acquisition and monitoring functions for current, voltage, temperature, pressure, etc.

Safety Interlock and Protection: Equipped with dual safety protection strategies for hardware and software, with three-level alarm parameters settable via upper computer software.

Performance Testing: Equipped with testing functions for fuel cell polarization curve testing, steady-state operation, dynamic response testing, activation testing, durability testing, etc.

Stability and Reliability: Built-in multifunctional controller with stable performance; equipped with automatic/manual operation modes, allowing reliable operation unattended for 24 hours.

 

1.4 Product Advantages

High Control Stability: Gas flow control ±0.8% RD + 0.2% F.S.; pressure control ±2 kPa; steady-state temperature control ±1℃.

High Measurement Accuracy: Temperature ±0.5℃; pressure ±0.5% F.S.; conductivity ±1% F.S.; coolant flow ±1% F.S.

High Integration Level: Highly integrated equipment, compact layout, aesthetically pleasing design, convenient operation, and complete interface functions.

Strong Data Processing Capability: Able to automatically collect, analyze, and process data, generating detailed test results, including charts, data lists, etc.

High Equipment Safety: Complete safety protection and interlock functions, with three-level safety alarm limits settable via upper computer.

Strong Equipment Reliability: Equipment has various automatic condition testing functions, allowing for 7×24 hours of unattended operation.

Multiple Function Expandability: Can be expanded to achieve anti-reverse polarity testing; can be expanded to achieve high-temperature dew point testing; can be expanded to achieve mixed gas function for anode and cathode; can integrate electrochemical workstation for electrochemical testing; can be expanded to achieve polarization loss decomposition, EIS data analysis, CV data analysis, LSV data analysis functions, etc.

 

1.5 Product Parameters

1.5.1 Desktop Fuel Cell Test Bench

Model

GR-FCTS-SC100

GR-FCTS-SC300

Rated Power

100W

300W

Fuel Cell Type

PEM Fuel Cell

System Module

Technical Indicators

Specific Parameters

Gas Flow Control

Anode Flow

0.02~2SLPM

0.06~6SLPM

Cathode Flow

0.05~5SLPM

0.2~20SLPM

Control Accuracy

±(0.8%RD+0.2%F.S.)

Nitrogen purging

Equipped with automatic/manual nitrogen purging function before/after testing, customizable purging time

Gas

Pressure control

Control method

Manual/Automatic

Back pressure control

Control range: 0~300kPa; Control accuracy: ±2kPa

Temperature control

Control method

PID

Temperature control

RT~90℃; Steady-state temperature control accuracy: ±1℃; Heating rate: 1~4℃/min

Gas humidification control

Humidification method

Bubbling

Dew point temperature

RT~90℃; Steady-state temperature control accuracy: ±1℃; Heating rate: 1~4℃/min

Dry/wet switching

Equipped with automatic dry/wet switching function; equipped with automatic water replenishment humidification

Voltage inspection

Voltage inspection

Equipped with single cell voltage inspection; Number of channels: customizable; Range: ±2.5V; Accuracy: ±1mV; Alarm limit can be set

Electronic load

Working mode

Constant voltage, constant current, constant power, programmable automatic operation

Voltage

40V

Current

200A

Protection function

Hardware protection

Pressure switch (can control pressure relief protection); Temperature switch; Emergency stop switch

Software protection

Hydrogen leakage; Over-temperature protection; Over-pressure protection; Under-voltage protection; Flow protection; Electronic load fault protection, etc.

Whole system

Controller

PLC

Upper computer

Optional C# or Labview

Communication interface

LAN

Power supply

AC220V/50Hz or AC380V/50Hz

Overall structure

Desktop type

Optional functions

Fixture; Anti-reverse test; High-temperature dew point test (bench type); Anode and cathode mixed gas (bench type); Electrochemical workstation; Electrochemical testing; Polarization loss decomposition; EIS data analysis; CV data analysis; LSV data analysis functions

Note: Can be upgraded or downgraded according to requirements.

1.5.2 Fuel cell stack test bench

Model

GR-FCTS-S1K

GR-FCTS-S5K

GR-FCTS-S10K

GR-FCTS-S30K

GR-FCTS-S50K

GR-FCTS-S100K

GR-FCTS-S200K

GR-FCTS-S400K

Rated Power

1kW

5kW

10kW

30kW

50kW

100kW

200kW

400kW

Fuel Cell Type

PEM Fuel Cell

System Module

Technical Indicators

Specific Parameters

Gas Flow Control

Anode Flow

20SLPM

100SLPM

200SLPM

800SLPM

1000SLPM

2000SLPM

5000SLPM

8000SLPM

Cathode Flow

80SLPM

400SLPM

800SLPM

2000SLPM

4000SLPM

8000SLPM

15000SLPM

25000SLPM

Control Accuracy

±(0.8%RD+0.2%F.S.)

Nitrogen purging

Equipped with automatic/manual nitrogen purging function before/after testing, customizable purging time

Gas pressure control

Control method

Manual/Automatic

Back pressure control

Control range: 0~300kPa; Control accuracy: ±2kPa

Gas temperature control

Control method

PID

Temperature control

RT~90℃; Steady-state temperature control accuracy: ±1℃; Heating rate: 1~4℃/min

Gas humidification control

Humidification method

Bubbling + Spraying

Dew point temperature

RT~90℃; Steady-state temperature control accuracy: ±1℃; Heating rate: 1~4℃/min

Dry/wet switching

Equipped with automatic dry/wet switching function; equipped with automatic water replenishment humidification

Cooling liquid control

Cooling medium

Deionized water/Ethylene glycol

Cooling flow

5L/min

20L/min

50L/min

120L/min

200L/min

400L/min

600L/min

1200L/min

Water replenishment function

Automatic water replenishment + Exhaust

Voltage inspection

Voltage inspection

Equipped with single cell voltage inspection function; Number of channels: customizable; Range: ±2.5V; Accuracy: ±1mV; Alarm limit can be set

Electronic load

Working mode

Constant voltage, constant current, constant power, programmable automatic operation

Voltage

Provide customized services according to actual needs

Current

Provide customized services according to actual needs

Protection function

Hardware protection

Pressure switch (can control pressure relief protection); Temperature switch; Emergency stop switch

Software protection

Hydrogen leakage; Over-temperature protection; Over-pressure protection; Under-voltage protection; Flow protection; Electronic load fault protection, etc.

Whole system

Controller

PLC

Upper computer

Optional C# or Labview

Communication interface

LAN

Power supply

AC220V/50Hz or AC380V/50Hz

Overall structure

Bench type

Cabinet/container type

Optional functions

Anti-reverse test; High-temperature dew point test; Anode and cathode mixed gas; Electrochemical testing; Polarization loss decomposition and EIS data analysis functions; Hydrogen circulation function

 

Note: Can be upgraded or downgraded according to requirements.

Beijing Ge Rui Energy Technology Co., Ltd.

 

Key words:

Fuel Cell Stack Test Equipment丨Fuel Cell丨Control

Next:

Related Products


AEM Electrolyzer Test Bench

Large Area Fuel Cell Partition Detection Device

Fuel Cell Partition Detection Fixture

Visualized PEM Electrolyzer Fixture

Online consultation


Product Name:

Submit