ALK Electrolyzer Test Bench
The GR-WETS-ALK-S10K series electrolytic water hydrogen production tank testing equipment is designed to provide an accurate and reliable testing platform for electrolytic water hydrogen production tanks. It can be used for testing the performance, functionality, and coordination of ALK electrolytic cells, meeting the testing needs of electrolytic cells. The system consists of the tested electrolytic cell, gas-liquid separator, heating tank, water replenishment pump, cooling system, control power supply, and more. All subsystems are integrated into a single testing system that meets hydrogen safety system requirements, equipped with corresponding hydrogen concentration monitoring devices, and features appropriate safety interlock functions.
Classification:
Product Details
ALK Electrolyzer Test Bench Product Power Level Overview
| Serial Number |
Number |
Name |
Model |
| 1 |
1 |
500W ALK Electrolyzer Test Bench |
GR-WETS-ALK-SC500 |
| 2 |
1kW ALK Electrolyzer Test Bench |
GR-WETS-ALK-S1K |
|
| 3 |
5kW ALK Electrolyzer Test Bench |
GR-WETS-ALK-S5K |
|
| 4 |
25kW ALK Electrolyzer Test Bench |
GR-WETS-ALK-S25K |
|
| 5 |
100kW ALK Electrolyzer Test Bench |
GR-WETS-ALK-S100K |
|
| 6 |
500kW ALK Electrolyzer Test Bench |
GR-WETS-ALK-S500K |
|
| 7 |
1MW ALK Electrolyzer Test Bench |
GR-WETS-ALK-S1M |
|
| 8 |
5MW ALK Electrolyzer Test Bench |
GR-WETS-ALK-S5M |
|
| 9 |
2 (Multi-channel) |
4-channel 100W ALK Electrolyzer Test Bench (Fully Independent) |
GR-WETS-ALK-SC100X4D |
| 10 |
4-channel 100W ALK Electrolyzer Test Bench (Fully Shared) |
GR-WETS-ALK-SC100X4G |
ALK Electrolyzer Test Bench Product Overview
1.1 Product Images
| Serial Number |
Type |
Image |
Image |
| 1 |
ALK Electrolyzer Test Bench |
|
|
| 2 |
|
|
|
| 3 |
Multi-channel ALK Electrolyzer Test Bench |
|
|
1.2 Product Overview
The GR-WETS-ALK series electrolyzer test bench is designed to provide an accurate and reliable testing platform for electrolyzers. This test bench has undergone multiple upgrades and optimizations based on the performance of existing products in the industry. It consists of an electrolyte circulation system, nitrogen purging unit, gas-liquid separation unit, gas analysis pretreatment unit, PLC acquisition and control unit, human-machine operation unit, and safety monitoring unit, and uses the company's self-developed system testing software to meet the testing needs for polarization curves, hydrogen production energy consumption efficiency, hydrogen quality testing, and product lifespan.
1.3 Product Functions
Nitrogen Purging: Automatic nitrogen purging function before and after testing, and during equipment failure/shutdown.
Electrolyte Control: Wide range, high precision, and stable control of circulating electrolyte flow to meet various testing needs; includes alkaline solution concentration monitoring; features heating, liquid level monitoring, and automatic water replenishment for circulating electrolyte.
Gas-Water Separation: Efficient gas-water separation design, including gas-liquid separation, washing, condensation dehumidification, and drying devices.
Pressure Control: Automatic back pressure control for anode/cathode.
Flow Detection: High precision online measurement of gas flow.
Data Acquisition and Storage: Real-time acquisition and monitoring of data such as current, voltage, temperature, pressure, and circulating electrolyte flow.
Safety Interlock and Protection: Dual safety protection strategy with software settings for three-level alarm parameters.
Performance Testing: Testing functions for electrolyzer polarization curve, small chamber consistency, durability, sensitivity, etc.
Stability and Reliability: 24-hour unattended operation capability.
1.4 Product Advantages
High control stability: Steady-state temperature control ±1℃; pressure control ±0.5%F.S.; electrolyte flow control ±1%F.S.
High measurement accuracy: Temperature ±0.5℃; pressure ±0.5%F.S.; circulating electrolyte flow ±1%F.S.; gas flow ±0.8%RD+0.2%F.S.
High integration level: Highly integrated equipment, compact layout, aesthetically pleasing design, convenient operation, and complete interface functions.
Strong data processing capability: Able to automatically collect, analyze, and process data, generating detailed test results, including charts and data lists.
High equipment safety: Complete safety protection and interlock functions, with three-level safety alarm limits settable via the upper computer.
Strong equipment reliability: Equipment has various automatic condition testing functions, capable of 7×24 hours unattended operation.
Multiple functional expansion capabilities: Can integrate with electrochemical workstations for electrochemical testing; can expand to achieve electrolyzer polarization loss decomposition, EIS data analysis functions, etc.
1.5 Product Parameters
1.5.1 ALK Electrolyzer Test Bench
| Model |
GR-WETS-ALK-SC500 |
GR-WETS-ALK-S1K |
GR-WETS-ALK-S5K |
GR-WETS-ALK-S25K |
GR-WETS-ALK-S100K |
GR-WETS-ALK-S500K |
GR-WETS-ALK-S1M |
GR-WETS-ALK-S5M |
|
| Rated Power |
500W |
1kW |
5kW |
25kW |
100kW |
500kW |
1MW |
5MW |
|
| Electrolyzer Type |
ALK Electrolyzer |
||||||||
| System Module |
Technical Indicators |
Specific Parameters |
|||||||
| Electrolyte Circulation Module |
Medium |
30% KOH Solution |
|||||||
| Circulation Mode |
Dual-side Supply |
||||||||
| Alkaline Solution Concentration |
Equipped with alkaline solution concentration detection function; detection range: 0~40%; accuracy: ±1%F.S. |
||||||||
| Alkaline Solution Flow |
1L/min |
2L/min |
10L/min |
50L/min |
160L/min |
560L/min |
800L/min |
4000L/min |
|
| Temperature Control |
RT~90℃; steady-state temperature control accuracy: ±1℃; heating rate: 1~4℃/min |
||||||||
| Automatic Water Replenishment |
Equipped with |
||||||||
| Hydrogen/Oxygen System Module |
Hydrogen Flow |
2.5SLPM |
5SLPM |
25SLPM |
125SLPM |
500SLPM |
2500SLPM |
5000SLPM |
25000SLPM |
| Back Pressure Range |
0~1.6MPa; control accuracy: ±1%F.S.; equipped with pressure difference and liquid level difference adjustment functions. |
||||||||
| Dehydration function |
Equipped with gas-liquid separation, washing, condensation dehumidification, drying |
||||||||
| Nitrogen purging |
Purging function |
Equipped with automatic/manual nitrogen purging function before/after testing, customizable purging time |
|||||||
| Gas analysis |
Hydrogen in oxygen |
Range: 0~4% VOL; Accuracy: ±2% F.S. (calibration available in the range of 0~5% VOL) |
|||||||
| Power module |
Operating mode |
Constant pressure, constant current, constant power, programmable automatic operation |
|||||||
| Voltage |
Custom services provided based on actual needs |
||||||||
| Current |
Custom services provided based on actual needs |
||||||||
| Voltage inspection |
Voltage inspection |
Equipped with individual voltage inspection function; Number of channels: customizable; Range: ±3V; Accuracy: ±1mV; Alarm limit can be set |
|||||||
| Whole system |
Controller |
PLC |
|||||||
| Upper computer |
Optional C# or Labview |
||||||||
| Communication interface |
LAN |
||||||||
| Power supply |
AC220V/50Hz or AC380V/50Hz |
||||||||
| Overall structure |
Bench type |
Cabinet/container type/skid-mounted type |
|||||||
| Optional functions |
Oxygen flow detection; Oxygen detection in hydrogen; Dew point detection; Electrochemical testing; Polarization loss decomposition and EIS data analysis functions |
||||||||
Note: Upgrades or downgrades can be made as required.
1.5.2 Multi-channel ALK electrolyzer test bench
| Model |
GR-WETS-ALK-SC100X4D |
GR-WETS-ALK-SC100X4G |
|
| Single channel rated power |
100W |
||
| Electrolyzer Type |
ALK Electrolyzer |
||
| Channel form |
4 independent channels |
4 shared channels |
|
| System Module |
Technical Indicators |
Specific Parameters |
|
| Electrolyte Circulation Module |
Medium |
30% KOH Solution |
|
| Circulation Mode |
Dual-side liquid supply, 4 independent channels |
||
| Alkaline Solution Concentration |
All 4 channels equipped with alkali liquid concentration detection function Detection range: 0~40%; Accuracy: ±1% F.S. |
Shared 1 set of alkali liquid concentration detection function Detection range: 0~40%; Accuracy ±1% F.S. |
|
| Alkaline Solution Flow |
0.05~0.5L/min |
||
| Temperature Control |
RT~90℃; steady-state temperature control accuracy: ±1℃; heating rate: 1~4℃/min |
||
| Automatic Water Replenishment |
Equipped with |
||
| Hydrogen/Oxygen System Module |
Hydrogen Flow |
Single channel 0~0.5SLPM |
0~2SLPM |
| Back Pressure Range |
4 independent channel back pressure, 0~1.6MPa |
4 shared channel back pressure, maximum 0~1.6MPa |
|
| Dehydration function |
All 4 channels equipped with gas-liquid separation, washing, condensation dehumidification, drying |
Shared 1 set of gas-liquid separation, washing, condensation dehumidification, drying |
|
| Nitrogen purging |
Purging function |
Equipped with automatic/manual nitrogen purging function before/after testing, customizable purging time |
|
| Gas analysis |
Hydrogen in oxygen |
Range: 0~4% VOL; Accuracy: ±2% F.S. (calibration available in the range of 0~5% VOL) |
|
| Single channel power module |
Operating mode |
Constant pressure, constant current, constant power, programmable automatic operation |
|
| Voltage |
0~20V |
||
| Current |
0~100A |
||
| Voltage inspection |
Voltage inspection |
Equipped with individual voltage inspection function; Number of channels: customizable; Range: ±3V; Accuracy: ±1mV; Alarm limit can be set |
|
| Whole system |
Controller |
PLC |
|
| Upper computer |
Optional C# or Labview |
||
| Communication interface |
LAN |
||
| Power supply |
AC220V/50Hz |
||
| Overall structure |
Bench type |
||
| Optional functions |
Independent detection/switching inspection of oxygen flow; Switching inspection of hydrogen in oxygen; Independent detection/switching inspection of oxygen in hydrogen; Dew point detection; Electrochemical testing; Polarization loss decomposition and EIS data analysis functions |
||
Note: Upgrades or downgrades can be made as required.